Products

SCB Series Epoxy Resin 10kV Dry Type Transformer

SCB series epoxy-resin 10kV Dry Type Transformer with silicon-steel core, vacuum-cast high-voltage winding, copper-foil low-voltage winding, F-class insulation, IP20 standard protection and optional IP23 enclosure.
  • Series: SCB
  • High-voltage class: 10 kV series
  • Core material: Silicon steel
  • High-voltage winding: Vacuum-cast winding

Description

Kampa 10kV dry type transformers are designed for indoor medium-voltage distribution where fire safety, compact installation and low routine maintenance are important. Typical systems step 10kV or 10.5kV down to 0.4kV, with the transformer configuration selected according to load, installation environment, utility requirements and applicable project standards.

The SCB cast-resin series can be configured for industrial plants, commercial buildings, data centers, hospitals, rail facilities, renewable-energy projects and packaged substations. Capacity, winding material, voltage ratio, impedance, enclosure and accessories should be confirmed against the project single-line diagram before production.

Construction

1. Iron Core

Made of high-quality silicon steel sheet, with fine processing, effectively reducing no-load loss and operating noise.
Adopt reinforced structure and shockproof design, long-term operation without loosening, stable and durable.

2. Winding

High-voltage winding with vacuum casting, excellent pressure resistance and low partial discharge.
Low-voltage copper foil winding, strong short-circuit resistance, stable output and low power loss.

3. Insulation System

Adopt high-temperature resistant F-class insulation material.
Integrated epoxy resin structure, crack-proof, aging-resistant, good heat dissipation.

4. Casting Technology

Professional vacuum pouring process, no internal bubbles.
High-density resin encapsulation, improve overall insulation and safety performance.

5. Protection & Housing

Standard IP20 protection grade, optional IP23 for outdoor use.
Lightweight aluminum alloy frame, compact structure, easy installation.

6. Core Advantages

Flame retardant & explosion-proof, no oil leakage risk.
Low noise, energy saving and low consumption.
Moisture-proof and dust-proof, free of daily maintenance.

7. Temperature Control System

Equipped with intelligent temperature controller.
Real-time temperature monitoring, over-temperature alarm and trip protection.
额定容量
(千伏安)
高压
(千伏)
敲击范围
LV
(千伏)
住宿组
空载损失
75℃
负载损失
空载损失
短路阻抗
30
6
6.3
6.6
10
10.5
11
±5%
±2×2.5%
0.4
Dyn11
190
710
2.4
4
50
270
1000
2.4
80
370
1380
1.8
100
400
1570
1.8
125
470
1850
1.6
160
540
2130
1.6
200
620
2530
1.4
250
720
2760
1.4
315
880
3470
1.2
400
980
2990
1.2
500
1160
4880
1.2
630
1340
5880
1.0
630
1300
5960
1.0
6
800
1520
6960
1.0
1000
1770
8130
1.0
1250
2090
9690
1.0
1600
2450
11730
1.0
2000
3050
14450
0.8
2500
3600
17170
0.8
1600
2450
12960
1.0
8
2000
3050
15960
0.8
2500
3600
18890
0.8

50611 (1)

50611 (2)

Where 10kV Dry Type Transformers Are Used

  • Factories and processing plants: indoor distribution close to production loads.
  • Commercial buildings and hospitals: oil-free equipment for occupied or fire-sensitive areas.
  • Data centers: configurations engineered for redundancy, harmonics and critical-load requirements.
  • Metro, tunnel and airport projects: installations where fire behaviour and environmental class must be specified.
  • Solar and energy-storage projects: designs matched to converter duty, harmonics and bidirectional loading.
  • Packaged substations: coordinated with medium-voltage switchgear and low-voltage distribution equipment.
  • Marine or humid locations: only with a design and enclosure selected for the actual condensation, salt and pollution conditions.

FAQ

What insulation system is described?

F-class insulation with epoxy-resin casting.

Which enclosure ratings are listed?

IP20 standard and IP23 optional.

What should be provided for selection?

Provide capacity, voltage ratio, connection group, impedance, enclosure rating, cooling, temperature-control requirements, and installation conditions.

What is the usual voltage ratio of a 10kV dry type transformer?

A common distribution ratio is 10/0.4kV, but 10.5/0.4kV, 11/0.4kV and other project-specific ratios are also used. The correct ratio must match the utility system and required low-voltage bus.

Request Quote

Tell us your specifications, quantity, or application scenario and we will reply with a tailored quote.

+86-13362788157 Phone tony@elexpert.cn E-mail Chat on WhatsApp WhatsApp